LMG II products specifications
Please oder LMG in combination of a sensor and a display unit.
Sensor
Å@Å@Å@Å@ MODEL
ITEMS |
ÇkÇlÇf
ÇOÇPÇUáU
|
ÇkÇlÇf
ÇPÇQÇUáU
|
ÇkÇlÇf
ÇRÇOÇOáU
|
ÇkÇlÇf
ÇRÇOÇTáU
|
ÇkÇlÇf
ÇUÇOÇUáU
|
ÇkÇlÇf
ÇWÇOÇOáU
|
ÇkÇlÇf
ÇWÇOÇTáU
|
ÇkÇlÇf
ÇPÇTÇOÇTáU
|
ÇkÇlÇf
ÇvÇQÇQÇOÇTáU
|
PDF |
PDF |
PDF |
PDF |
PDF |
PDF |
PDF |
PDF |
PDF |
Light source |
Visible Diode Laser (Wave Length : 655nm) |
Measuring range
(mm) |
0.01 - 2
|
0.05 - 12
|
0.2 - 30
|
0.2 - 30
|
0.5 - 60
|
0.5 - 80
|
0.5 - 80
|
0.7 - 150
|
0.7 - 220
|
Resolution |
ÇOÅDÇOÇTÅ@ÅiÇPÅjÉ Çç |
ÇOÅDÇPÅiÇPÅjÉ Çç |
ÇPÉ Çç |
ÇOÅDÇOÇOÇOÇOÇOÇQÅi0.0001Åj inch |
ÇOÅDÇOÇOÇOÇOÇPÅi0.0001Åj inch |
ÇOÅDÇOÇOÇOÇP inch |
Accuracy
*1
|
Total
(µm) |
Å}0.3 |
Å}ÇP
|
Å}ÇQ
|
Å}ÇR
|
Å}ÇS
|
Å}ÇS
|
Å}ÇT
|
Å}ÇPÇQ(Å}ÇTÅj*2 |
Å}ÇPÇT (Å}ÇTÅj*3 |
Linearity
(µm) |
Å}0.3 |
Å}0.5 |
Å}1.5 |
Å}2.0 |
Å}2.5 |
Å}2.5 |
Å}4 |
Å}8(Å}4)
*2 |
Å}12(Å}4)
*3 |
Repeatability
(µm) |
Å}0.2 |
Å}0.2 |
Å}0.3 |
Å}0.5 |
Å}0.5 |
Å}0.5 |
Å}ÇP
|
Å}2(Å}ÇP)
*2 |
Å@Å}2(Å}ÇP)
*3 |
Scanning freq. |
1800 / s |
Scanning speed (m/s) |
42 |
110
|
175
|
175
|
350
|
350
|
420
|
560
|
420
|
Operation temp
(deg.C) |
0 - 45
|
Weight
(kg)
|
Trasmitter |
Å@Å@Å@Å@
|
Å@Å@Å@
|
1.7 |
Å@Å@
|
2.2 |
5.0 |
4.0 |
7.5 |
20.0 |
Receiver |
Å@Å@
|
Å@Å@Å@
|
1.0 |
Å@Å@
|
1.0 |
3.0 |
2.0 |
4.5 |
6.0 |
Base plate |
Å@Å@
|
Å@Å@
|
1.5 |
Å@Å@
|
1.6 |
4.0 |
3.0 |
4.5 |
7.0 |
Weight(kg)
Total |
2.0 |
2.5 |
4.2 |
3.0 |
4.8 |
12.0 |
9.0 |
16.5 |
33.0 |
*1 At ambient temparature of 20±5
deg.C. Number of data to obtain a mean value
: More than 512 data
(Display interval : More than 0.3ms)
*2 ( ) : Up to 80mm
*3 ( ) : At lower measuring area
Display Unit
Specifications
|
D5
|
MIII
|
Number of connecting sensors |
1 |
2 |
Display
|
Two measuring values can be displayed at the same time. |
Measuring values of two sensors can be displayed alternately with a switch. |
Display unit |
Selectable between mm and inch |
mm |
Display interval
|
0.56ms to 4.5s Selectable : 5 kinds of interval
registered |
Nominal value
|
Pre-settable for each measuring mode
|
Tolerance value
|
Pre-settable each Hi tolerance and Lo tolerance
|
Measuring mode
|
Selectable between 2 point diameters and
3 point gaps.
|
Data processing
|
Mean value, Max. value, Min.value, Max-Min.
value, etc.
|
Data output
|
RS-232C, Analog±10V(Option :GP-IB,
Centronics, BCD)
|
Alarm
|
Out of tolerance: Lamp on relay output
|
Others
|
Measurement by input signal. Offset. Zeroset,
Calibration etc.
|
Weight
|
4kg
|
Power Source
|
AC85V - 264V 50/60Hz 30VA
|
Standard accessories
- Connecting cable between transmitter and
receiver ··········
1
- Connecting cable between sensor and display(4m)Å@··········
1
- Power cable (2m) ·························································
1
- Operation Manual ·························································
1
Options
- Transparent object measuring function
- Multi-segments measuring function of outer
diameter and gap.
- BCD,Centronics & GP-IB interface
- Dustproof hood(for protection against dust)
- Design & production of measureing line
[Back to home]
[Back to LMG home] |